DataBank

DataBank Data Center

  • 256,000 sq ft building
  • 38,000 sq ft data center
  • No advertising of DataBank name (plain wrapper)
  • Security managed 24/7 by permanently assigned staff  managed by a third party security company.

Zoned access throughout Data Center

  • Biometric hand scanner requires ID card access and hand geometry measurements
  • Customer data center access and contacts managed via C-Cure management system.
  • Current government-issued picture ID required
  • Second hand scans to gain access to raised floor Biometric scanner captures 3D measurements of hand

Security cameras

  • Multiple 360 degree cameras with 10x zoom
  • High speed recorders with DV cassette tapes
  • Hard drives to eliminate down time for tape swaps and over recording
  • Minimum 30 day tape storage

Power

  • TXU fault tolerant electrical grid
  • 3000 amps of 480v input power – Riser A
  • 3000 amps of 480v input power – Riser B
  • 800 KVA MGE UPS Systems  - Riser A
  • 800 KVA MGE UPS Systems  - Riser B
  • 2.0 megawatt generator (5000 gallon tank) Riser A
  • 2.0 megawatt generator (5000 gallon tank) Riser B

Two utility feeds from independent substations

  • Diverse paths to the building
  • Feeds to building are encased in concrete
  • Fed from two independent substations
  • Separate transformers fed from both utility sources for redundancy

HVAC cooling system

  • Data Center HVAC system includes (28) 30 Ton Liebert AHUs.
  • Entire system is designed with N+2 redundancy
  • Liebert Leak Detect System

Network facilities - Main Node Room

  • Multiple fiber providers for diversity - provides diversity and redundancy
  • Each vendor can deliver additional bandwidth capacity with minimal turn-around time
  • Can be delivered using existing ‘lit’ fiber
  • Fiber pathways into the Data Center are truly diverse
  • Fiber enters building in steel conduit from multiple points in the building

Internet Service Providers

  • 2 Gbps Direct Fiber – Level 3 AS3356
  • 2 Gbps Direct Fiber – Savvis AS3561
  • 2 Gbps Direct Fiber – Sprint AS1239
  • 2 Gbps Direct Fiber – Time Warner AS4323
  • 2 Gbps Direct Fiber - Broadwing AS16852

   

Savvis Data Center

  • 153,800 sq ft building
  • No advertising of SAVVIS name (plain wrapper)
  • Interior and exterior security managed 24/7 by permanently assigned staff of Wackenhut guard

Zoned access throughout Data Center

  • Biometric hand scanner requires ID card access and hand geometry measurements
  • Customer IDC access and contacts managed via Siebel
  • Current government-issued picture ID required
  • ID badge and biometric hand scan to man trap with badge reader
  • Second hand scans to gain access to raised floor Biometric scanner captures 3D measurements of hand

Security cameras

  • Multiple 360 degree cameras with 10x zoom
  • More than 100 fixed cameras
  • High speed recorders with DV cassette tapes
  • Hard drives to eliminate down time for tape swaps and over recording
  • Minimum 30 day tape storage

Generator power

  • Backup power
  • Multiple CAT Diesel 20 megawatt generators
    Minimum 24 hour fuel storage
  • Agreements with two major carriers to provide additional diesel fuel
  • Generators assumes building load within 20 seconds
  • Generators are tested on weekly basis under load
  • Tanks are kept at least 80% full at all times

Two utility feeds from independent substations

  • Diverse paths to the building
  • Feeds to building are encased in concrete
  • Fed from two independent substations
  • Separate transformers fed from both utility sources for redundancy

HVAC chiller systems

  • Hosting space HVAC system includes (16) AHUs and (16) ACCUs manufactured by Trane
  • AHUs are DX type and located in the mechanical mezzanine; the ACCUs are located on the roof
  • There is adequate capacity to withstand a HVAC unit failure or an entire bus failure
    Cooling is provided by both overhead and under floor air
  • HVAC systems have wetted media for humidification, VFDs for each supply fan, exhaust fans to control building pressure, and economizers to utilize cool outside air
  • Separate Dectron outside air handling units provide conditioned air for the hosting space
  • UPS Room cooling is provided by Trane RTUs in a N+1 configuration
  • Node room cooling is provided by Liebert DX CRAC units in a N+1 configuration

Network facilities - Main Node Room

  • Multiple fiber providers for diversity - provides diversity and redundancy
  • Each vendor can deliver additional bandwidth capacity with minimal turn-around time
  • Can be delivered using existing ‘lit’ fiber
  • Fiber pathways into the Data Center are truly diverse
  • Fiber enters building in steel conduit from multiple points in the building

Network features include:

  • Based on industry-leading Juniper core routers and Cisco equipment specifically designed for the needs of Tier 1 "carrier-class" customers
  • OC-48/OC-192 backbone trunks, supporting MPLS protocol
  • AS3561 is consistently rated over time as having the lowest latency, lowest packet loss, and highest reliability
  • SAVVIS firmly segregates Layer-2 (transmission) and Layer-3 (routing)
  • Layer-2 is ATM-based for traffic management
  • Core network is designed for “zero” packet loss
  • SAVVIS is moving to more efficient MPLS Layer 2 protocol